Visitability in States
Location FLORIDA TEXAS GEORGIA VERMONT KANSAS (Pending) OREGON (Failed) MINNESOTA
  1989 1999 2000 2000 2001 2001 2001
Types of Homes All new single family houses, duplexes, triplexes, condominiums, and townhouses. New single family houses, duplexes, triplexes New single family homes  New residential homes; one family or multi-family  New single family houses, duplexes, triplexes New single family or multi-family homes  New single family duplex, triplex, and multi level townhouses
               
Subsidized/ Unsubsidized   Subsidized (state or federal funds) Subsidized (state or federal funds) Unsubsidized and Subsidized (state or federal funds) Subsidized (state or federal funds) Unsubsidized (Applies only to projects financed in whole or in part by the Minnesota Housing Finance Agency)
               
Architectural Requirements:            
1. Entrance to Home   At least one no-step entrance on accessible route; minimum opening 36" At least one no-step entrance on accessible route; minimum opening 36" Not included At least one no-step entrance on accessible route, minimum opening 32" At least one accessible entrance At least one no-step entrance
               
2. Interior Doors   All Interior doors on first floor minimum 32"  All Interior doors on first floor minimum 32"  First floor interior doors between rooms that are at least 34" or open doorways that are 32" All doors or openings minimum 32" All interior doors 32" All interior doors 32"
               
3. Accessible Route   36" wide level hallways on first floor 36" wide level hallways on first floor 36" wide level hallways  36" wide level route through main floor of unit 36" wide hallways and passageways on first floor  
               
4. Bathroom Walls   First Floor bathroom walls reinforced First Floor bathroom walls reinforced Bathroom walls reinforced Bathroom walls reinforced    
               
5. Light switches, thermostat, electrical outlets, electrical panels, etc.   For first floor, max 48" height, minimum 15" height For first floor, max 48" height, minimum 15" height Environmental and utility controls and outlets located at heights in compliance with standards of Vermont Access Board Reachable outlets, switches, thermostats (if multiple controls only one has to be accessible)    
               
6. Added Features / Comments Shall provide at least one bathroom, located with maximum possible privacy, where bathrooms are provided on habitable grade levels, with a door that has a 29-inch clear opening. Electrical box must be inside building on first floor Electrical box must be inside building on first floor       Half bath on main floor

 

Visitability in Cities
Location Atlanta, GA Austin, TX Irvine, CA* Urbana, IL Visalia, CA Tucson (Pima County), AZ Naperville, IL
  1992 1998 2000 2000 2001 2002 2002
Types of Homes Single family homes (apartments) New single family houses, duplexes, triplexes New single-family homes New single or multi-family dwellings New single-family homes New single-family homes  
               
Subsidized/ Unsubsidized Subsidized (city funds) Subsidized (city funds) No Subsidized (city funds) No All homes All homes
               
Architectural Requirements:              
1. Entrance to Home At least one no-step entrance on accessible route; minimum opening 32" At least one no-step entrance on accessible route; minimum opening 32"   At least one no-step entrance on accessible route; minimum opening 32" Zero-step entry usually through the garage. Zero-step entry Zero-step entry pending review and enactment
               
2. Interior Doors All interior doors minimum 32" opening and lever handles All Interior doors on first floor minimum 30" opening and lever handles   All doors or openings minimum 32" 32" minimum Wider doorways Wider first floor interior doors
               
3. Accessible Route 36" wide level route provided through main floor of unit 36" wide level route provided through main floor of unit   Corridors shall be at least 36" wide   Unknown  
               
4. Bathroom Walls Bathroom walls reinforced First Floor bathroom walls reinforced   Bathroom walls reinforced Bathroom walls reinforced Grab bars Bathroom walls reinforced
               
5. Light switches, thermostat, electrical outlets, electrical panels, etc. Max 48" height, minimum 15" height For first floor, maximum 42" height, minimum 15" height   Maximum 48" height, minimum 15" height   Lever handles on some doors Electrical outlets and light switches that are reachable by someone in a wheelchair.
               
6. Added Features / Comments     *Voluntary program - Home builders can offer any combination of 33 features to prospective home buyers including all of the above. (Eric Toles - Building Official) Additional requirements for accessible route to the home regarding landing, non-slip surfaces, and slope *Voluntary Visitable Home Program and Guidelines (Dennis Lehman - Building Official) Initial title "Visitability Code" changed to
"Inclusive Home Design Ordinance." (See http://www.co.pima.az.us/cob/test /pdf/020502AG.PDF)
Ordinance 02-19.